EchoCare Medical Anti-Decubitus Air Mattress with Pump
EchoCare Medical Anti-Decubitus Air Mattress with Pump
Couldn't load pickup availability
The EchoCare Doctor Series 1 Anti-Decubitus Air Mattress is designed to help prevent and relieve pressure ulcers for patients with limited mobility. It features an ultra-quiet pump, alternating pressure technology, durable PVC air cells, adjustable pressure settings, and medical-grade construction for home and hospital use.
Share

EchoCareMedical Anti-Decubitus Air Mattress with Pump
The EchoCare Doctor Series 1 Medical Anti-Decubitus
System provides effective pressure redistribution to help reduce the risk of
pressure ulcers for bedridden or immobile patients.
The mattress consists of 130 alternating air bubble cells
that inflate and deflate alternately every 12 minutes, helping improve blood
circulation and reduce continuous pressure on the skin.
The included ultra-quiet pump delivers stable airflow
with adjustable pressure according to the patient's weight, ensuring
personalized comfort. End flaps secure the mattress to the bed, while the
durable medical-grade PVC construction offers long-lasting performance.
Ideal for hospitals, nursing care, and home healthcare.
Features
- Alternating pressure therapy
- Helps prevent pressure ulcers
- Ultra-quiet air pump
- Adjustable pressure according to body weight
- 130 alternating air cells
- Durable medical-grade PVC material
- End flaps for secure mattress placement
- Includes repair kit
- Includes 1.5 m air hose
- Easy to install and operate
- Suitable for home and hospital use
- Supports users up to 150 kg
- Mattress Size: 200 × 90 × 7 cm
- 130 Air Bubble Cells
- Weight Capacity: 120–150 kg
- Ultra Quiet Pump
- Adjustable Pressure Control
- Pressure Range: 50–120 mmHg
- Air Output: 5–7 L/min
- Cycle Time: 12 minutes
- Power Consumption: 7W
- Pump Size: 23.5 × 12 × 9.5 cm
- Pump Weight: 1.4 kg
- Mattress Weight: 1.8–2.1 kg
- PVC Thickness: 0.3 mm
- Includes Repair Kit and 1.5 m Air Hose
- Suitable for Home & Hospital Use
How to Use
- Place the mattress on top of the bed with the air hose connectors positioned at the foot end.
- Secure the mattress using the end flaps.
- Connect the air hose to both the mattress and the pump.
- Hang the pump using the hook or place it on a flat surface.
- Plug the pump into a suitable power outlet.
- Adjust the pressure according to the user's weight.
- Allow the mattress to inflate completely before use.
Safety Warnings
- Read the instruction manual before use.
- Use only with the supplied pump.
- Do not puncture or cut the mattress.
- Keep away from open flames and excessive heat.
- Disconnect the power before cleaning.
- Do not exceed the maximum weight capacity.
- Regularly inspect the air hose and mattress for leaks or damage.
- Indoor use only.